TIA-942
EPI was established in the United Kingdom in 1987, now has its headquarters in Singapore. EPI has been in the data center industry for over 30 years, which is a tremendous accomplishment. EPI has ten branches worldwide and an extensive partner network that spans 60+ countries and over 130 cities, allowing them to provide services all over the world. EPI is Globally Authorized Conformity Assessment Body for ANSI/TIA-942 certifications.
TIA-942 Design Certification (DCDV) https://www.epi-ap.com/services/9/15/128/
TIA-942 Site/Facilities Certification (DCCC) https://www.epi-ap.com/services/9/15/129/
TIA-942 Ready Certification https://www.epi-ap.com/services/9/15/130/
Uptime Tier to ANSI/TIA-942 Upgrade https://www.epi-ap.com/services/9/15/114/
ISO/IEC TS 22237
ISO/IEC TS 22237 Design Certification (DCDV) https://www.epi-ap.com/services/9/31/149/
ISO/IEC TS22237 Site/Facilities Certification (DCCC) https://www.epi-ap.com/services/9/31/150/
Data Center Operations Standard (DCOS) Audit & Certification Service
Design & Audit Standards
The following list acts as reference material for the design and audit engagements. The list is not exhaustive and EPI takes special care to apply the current version of the standard wherever required.
ANSI/TIA-942 | Telecommunication Infrastructure Standard for Data Centers |
ANSI/TIA-568-C.0 | Generic Telecommunications Cabling for Customer Premises |
ANSI/TIA-568-C.1 | Commercial Building Telecommunications Cabling Standard |
ANSI/TIA-568-C.2 | Balanced Twisted-Pair Telecommunications Cabling and Components standard |
ANSI/TIA-568-C.3 | Optical Fiber Cabling Components Standard |
ANSI/TIA-569-D | Telecommunications Pathways and Spaces |
ANSI/TIA-606-B | Administration Standard for Telecommunications Infrastructure |
ANSI/TIA-607-C | Telecommunications Bonding and Grounding (Earthing) for Customer Premises |
ANSI/TIA-758-B | Customer-Owned Outside Plant Telecommunications Infrastructure Standard |
ANSI/ATIS-0600404 (DS3) | Network and Customer Installation Interfaces – DS3 and Metallic Interface Specification |
ANSI/TIA-604-10 | FOCIS 10B Fiber Optic Connector Intermateability Standard- Type LC |
ANSI/TIA-604-5 | FOCIS 5 Fiber Optic Connector Intermateability Standard- Type MPO |
ANSI/TIA-604-18 | FOCIS 18 Fiber Optic Connector Intermateability Standard- Type MPO- 16 |
ASHRAE | ASHRAE Thermal Guidelines for Data Processing Environments, Second Edition, 2009 |
ASHRAE | ASHRAE 2011 Thermal Guidelines for Data Processing Environments – Expanded Data Center Classes and Usage Guidance, 2011 |
NESC | National Electrical Safety Code® |
NFPA 101 | Life Safety Code® |
NEC (NFPA 70) | National Electrical Code® |
NFPA 75 | The standard for the Protection of Information Technology Equipment |
IEEE 1100 | Recommended Practice for Powering and Grounding Electronic Equipment |
IEEE 446 | Recommended Practice for Emergency and Standby Power Systems for Industrial and Commercial Applications |
ISA-71.04.2013 | Environmental Conditions for Process Measurement and Control Systems |
ISO 14001 | Environmental management systems |
ISO 14644 | Cleanrooms and associated controlled environments classification of air cleanliness |
ISO/IEC 20000 | Information technology — Service management |
ISO 22301 | Societal security – Business continuity management systems – Requirements |
ISO/IEC 27001 | Information technology – Security techniques – Information security management systems – Requirements |
ISO/IEC 27002 | Information technology – Security techniques – Code of practice for information security management |
ISO 31000 | Risk management — Principles and guidelines |
ISO/IEC 38500 | Information technology — Governance of IT for the organization |
OHSAS 18001 | Occupational Health and Safety Management Systems |